The first successful desensitization protocol in exenatide allergy: a case report.
Allergy Asthma Clin Immunol · 2023
Last updated 2026-05-28Two obese patients with type 2 diabetes experienced allergic reactions to exenatide, a GLP-1 drug, after taking 5 microgram doses twice daily. Doctors successfully used a 7-step desensitization process over about 3 hours to safely reintroduce the drug, allowing both patients to continue treatment without further allergic reactions for 3 months.
AI summary of the abstract below.
| Journal | Allergy Asthma Clin Immunol, 2023 |
|---|---|
| Citations | 7 |
| Relative citation ratio | 1.09 |
| NIH percentile | 53 |
| Molecules | exenatide |
Abstract
BACKGROUND: Glucagon-like peptide-1 (GLP-1) receptor agonists are important treatment options in obese patients with type 2 diabetes. To date, few immediate allergic reactions due to GLP-1 receptor agonists were reported. One report revealed that a patient with a level 1 anaphylaxis according to Brighton Criteria due to an exendin based GLP-1 receptor agonist was able to tolerate liraglutide (Human GLP-1 analogue), the alternative GLP-1 receptor agonist. Since exenatide is the only available GLP-1 receptor agonist covered by insurance in Turkey, a drug desensitization protocol, the only therapeutic method in hypersensitivity reactions used in case of absence of an alternative drug, was considered. Here, we report a successful desensitization protocol for the first time in two obese diabetic patients with an immediate hypersensitivity to exenatide.
CASE PRESENTATION: The first patient was a 47 year-old female. She was referred to our outpatient allergy clinic because of a generalized urticaria developed within minutes after the last dose, following a week of an exenatide BID 5 mcg/20 mcl treatment. Although the reaction was sudden onset, it did not meet the Brighton Criteria of anaphylaxis. The second patient was a 46 year-old female. She had a large local immediate injection site reaction that appeared 15 min following an exenatide BID 5 mcg/20 mcl injection. The injection site reaction was not accompanied by a systemic allergic reaction. We performed desensitization with exenatide to two patients who need GLP-1 receptor agonist treatment. Protocol was completed in 7 steps in approximately 3 h, with the aim of reaching the daily dosage of exenatide. Throughout this process, we observed that both cases tolerated the protocol without any complaints or complications. Following the protocol, the patients safely tolerated the treatment for 3 months.
CONCLUSIONS: We present the first successful desensitization protocol to exenatide in both local and/or systemic immediate hypersensitivity reactions and indicate the importance of desensitization in patients who do not have alternative therapies.
Verbatim abstract via PubMed 36639791 ↗
Related research
- Effects of Once-Weekly Exenatide on Cardiovascular Outcomes in Type 2 Diabetes.
- Exenatide once weekly versus placebo in Parkinson's disease: a randomised, double-blind, placebo-controlled trial.
- Efficacy and safety of exenatide once weekly versus sitagliptin or pioglitazone as an adjunct to metformin for treatment of type 2 diabetes (DURATION-2): a randomised trial.
- Efficacy and Safety of Once-Weekly Semaglutide Versus Exenatide ER in Subjects With Type 2 Diabetes (SUSTAIN 3): A 56-Week, Open-Label, Randomized Clinical Trial.
- Exenatide reduces reperfusion injury in patients with ST-segment elevation myocardial infarction.
- Exenatide and the treatment of patients with Parkinson's disease.
- Use of twice-daily exenatide in Basal insulin-treated patients with type 2 diabetes: a randomized, controlled trial.
- Exenatide once weekly versus liraglutide once daily in patients with type 2 diabetes (DURATION-6): a randomised, open-label study.