Simultaneous quantitative determination of liraglutide and insulin degludec in rat plasma by liquid chromatography-tandem mass spectrometry method and its application.

Biomed Chromatogr · 2020

Last updated 2026-05-28
JournalBiomed Chromatogr, 2020
Citations7
Relative citation ratio0.51
NIH percentile30
Molecules liraglutide
Conditions studied Type 2 Diabetes

Abstract

A simple, fast and high-throughput LC-tandem mass spectrometry method was developed and validated to simultaneously measure liraglutide and insulin degludec in rat plasma. After protein precipitation, plasma samples were subjected to gradient elution using an InertSustain Bio C column with 1000/20/1 water/acetonitrile/formic acid (v/v/v) and 1000/1 acetonitrile/formic acid (v/v) as the mobile phase. The method was validated from 1.00 to 500 ng/mL of liraglutide and insulin degludec. Further, the extraction recovery from the plasma was 41.8%-49.2% for liraglutide and 56.5%-69.7% for insulin degludec. Intra- and inter-day precision of liraglutide was 3.5%-9.4% and 8.4%-9.8%, respectively, whereas its accuracy was between -12.6% and -1.3%. Intra- and inter-day precision of insulin degludec was 5.2%-13.6% and 11.8%-19.1%, respectively, showing an accuracy between -3.0% and 9.9%. As a result, the method was successfully applied to a pharmacokinetics study of liraglutide and insulin degludec following a single-dose subcutaneous administration to rats.

Verbatim abstract via PubMed 32537846 ↗