GLPwatch

Efficacy and tolerability of the new autoinjected suspension of exenatide once weekly versus exenatide twice daily in patients with type 2 diabetes.

Diabetes Obes Metab · 2018

Last updated 2026-05-28

In a 28-week study of 375 people with type 2 diabetes, those using the new once-weekly exenatide autoinjector (2 mg) saw their blood sugar control improve by 1.4%, compared to a 1.0% improvement for those using twice-daily exenatide (10 µg). About 49% of the once-weekly group reached a target blood sugar level of less than 7.0%, compared to 43% in the twice-daily group. Gastrointestinal side effects were reported by 23% of the once-weekly group and 36% of the twice-daily group.

AI summary of the abstract below.

JournalDiabetes Obes Metab, 2018
Citations29
Relative citation ratio1.29
NIH percentile59
Molecules exenatide
Conditions studied Type 2 Diabetes

Abstract

AIMS: To simplify administration of aqueous exenatide once weekly, which requires reconstitution, the exenatide microspheres have been reformulated in a ready-to-use autoinjector with a Miglyol diluent (exenatide QWS-AI). This study compared the efficacy and safety of exenatide QWS-AI with the first-in-class glucagon-like peptide-1 receptor agonist exenatide twice daily (BID). MATERIALS AND METHODS: This randomized, open-label, controlled study in patients with type 2 diabetes using diet and exercise or taking stable oral glucose-lowering medication randomized patients 3:2 to either exenatide QWS-AI (2 mg) or exenatide BID (10 μg) for 28 weeks. The primary outcome was the 28-week change in glycated haemoglobin (HbA1c). A subset of patients completed a standardized meal test for postprandial and pharmacokinetic assessments. RESULTS: A total of 375 patients (mean HbA1c, 8.5% [69 mmol/mol]; body mass index, 33.2 kg/m ; diabetes duration, 8.5 years) received either exenatide QWS-AI (n = 229) or exenatide BID (n = 146); HbA1c was reduced by -1.4% and -1.0%, respectively (least-squares mean difference, -0.37%; P = .0072). More patients achieved HbA1c <7.0% with exenatide QWS-AI (49.3%) than with exenatide BID (43.2%; P = .225). Body weight was reduced in both groups (P = .37 for difference). Gastrointestinal adverse events (AEs) were reported in 22.7% (exenatide QWS-AI) and 35.6% (exenatide BID) of patients; fewer patients in the exenatide QWS-AI group withdrew because of AEs than in the exenatide BID group. Minor hypoglycaemia occurred most often with concomitant sulfonylurea use. CONCLUSIONS: Exenatide QWS-AI was associated with a greater reduction in HbA1c, similar weight loss and a favorable gastrointestinal AE profile compared with exenatide BID.

Verbatim abstract via PubMed 28685973 ↗

Related research